상세 보기
초록
Purpose: We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Materials and Methods: Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. Results: All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan-Meier analysis. Conclusion: The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.
키워드
- 제목
- 소아 환자에서 터널식중심정맥도관의 영상의학적 유치술
- 제목 (타언어)
- Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients
- 저자
- 김은지; 송순영; 조온구; 고병희; 김용수; 정우경; 이영호
- 발행일
- 2010-04
- 저널명
- 대한영상의학회지
- 권
- 62
- 호
- 4
- 페이지
- 351 ~ 355