한국인 기준여성 체적소형 모의체 개발

Development of the Reference Korean Female Voxel Phantom
  • 함보경
  • 조건우
  • 염연수
  • 정종휘
  • 김찬형
  • 외 1명

초록

The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.976×1.976×2.0619 mm3 and the voxel array size is 261×109×825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351×2.0351×2.0747 mm3 for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms. The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.976×1.976×2.0619 mm3 and the voxel array size is 261×109×825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351×2.0351×2.0747 mm3 for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

키워드

여성 체적소형 모의체컬러해부영상한국인 기준모의체몬테칼로유효선량Voxel phantomColor slice imageReference KoreanMonte CarloEffective dose
제목
한국인 기준여성 체적소형 모의체 개발
제목 (타언어)
Development of the Reference Korean Female Voxel Phantom
저자
함보경조건우염연수정종휘김찬형한민철
DOI
10.14407/jrp.2012.37.1.041
발행일
2012-02
저널명
방사선방어학회지
37
1
페이지
41 ~ 49