상세 보기
Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement
- Lim, Hyunyoung;
- Kim, Eugene;
- Kim, Soo Yeon;
- Kim, Ji-Yoon;
- Jung, Yundo;
- 외 3명
WEB OF SCIENCE
3SCOPUS
3초록
Background During transoral robot-assisted thyroidectomy, there is a risk of increasing intracranial pressure because the site of CO2 insufflation is narrow and close to the brain. Methods We analyzed the pre- to post-CO2 neck insufflation change in the optic nerve sheath diameter during transoral robot-assisted thyroidectomy. Changes in vital-signs, airway pressure, and arterial carbon dioxide pressure were analyzed along with postoperative complications. Results Among the 30 participants, the post-CO2 inflation mean optic nerve sheath diameter (5.64 +/- 0.54 mm) was higher than the pre-induction diameter (4.81 +/- 0.37 mm) with a mean difference of 0.83 (95% CI, 0.69-0.97; p < 0.001), but returned to baseline after CO2 deflation in most cases. One participant had sustained increased optic nerve sheath diameter (6.35 mm) associated with severe new-onset postoperative headache. Conclusion Transient elevation in the intracranial pressure during low-pressure CO2 neck insufflation in the transoral robot-assisted thyroidectomy did not appear to adversely affect patients.
키워드
- 제목
- Detection of increased intracranial pressure in trans-oral robotic thyroidectomy using optic nerve sheath diameter measurement
- 저자
- Lim, Hyunyoung; Kim, Eugene; Kim, Soo Yeon; Kim, Ji-Yoon; Jung, Yundo; Lee, Tagkeun; Kim, Nayeon; Tae, Kyung
- 발행일
- 2023-02
- 유형
- Article
- 저널명
- Head and Neck
- 권
- 45
- 호
- 2
- 페이지
- 329 ~ 336