겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season

초록

Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over 16℃ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452₩/household in Incheon city and from 3,521 to 26,268₩/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

키워드

Flush-out(플러쉬아웃)IAQ(실내공기질)Building energy simulation(건물에너지 시뮬레이션)Heating energy cost(난방에너지 비용)
제목
겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구
제목 (타언어)
Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season
저자
이기용김기한박준석
DOI
10.6110/KJACR.2016.28.3.110
발행일
2016-03
저널명
설비공학 논문집
28
3
페이지
110 ~ 114