저층 조적채움벽 철근콘크리트 골조의 내진보강 전후 동특성 변화

Dynamic Properties of a Lowrise Masonry-infilled RC Frame Building Before and After Seismic Retrofit

초록

In this study, a series of forced vibration testing and ambient vibration measurement were performed at a lowrise masonry-infilled reinforced concrete frame structure before and after seismic retrofit and its dynamic properties were extracted using system identification techniques. Also, analytical models which show similar dynamic properties to the measures ones were constructed. The system identification results showed that damping ratios in direction along which the dampers were installed has been increased. From the comparison between the analytical models, the effective stiffness of post-installed member and post-reinforced members(shear walls and damper frames) were only 50% of gross sectional stiffness of the members, which indicates that the these members were not fully integrated with the existing structure or members. In addition, support condition of post-installed footing has to be pinned in direction to match the dynamic properties, which is seemingly caused by the change of fixity of the soil due to the installation of new footing.

키워드

masonry-infilled frameforced vibration testingambient vibration measurementsystem identificationseismic retrofit조적채움벽 골조가진 실험미진동 계측시스템식별내진보강
제목
저층 조적채움벽 철근콘크리트 골조의 내진보강 전후 동특성 변화
제목 (타언어)
Dynamic Properties of a Lowrise Masonry-infilled RC Frame Building Before and After Seismic Retrofit
저자
유은종김민재김승남김지영최기선
DOI
10.7734/COSEIK.2015.28.3.293
발행일
2015-06
저널명
한국전산구조공학회논문집
28
3
페이지
293 ~ 300