Experimental study on spray break-up and atomization processes from GDI injector using high injection pressure up to 30 MPa

Citations

WEB OF SCIENCE

100
Citations

SCOPUS

122

초록

This paper focuses on the influence of injection pressures up to 30 MPa on single liquid jet break-up and atomization processes. For this purpose, a single jet from a multi-hole GDI injector has been characterized performing visualization and PDPA (phase Doppler particle analyzer) experiments. Using a thin sheet of light generated by a Nd:Yag laser and capturing a sequence of jet development images with a CCD camera, the internal structure was visualized. In order to quantify the droplet diameter and velocity, a 2-D PDPA system were carried out in addition to the spray visualization. Analyzing the images of the internal structure of jet and the result of PDPA, including droplet diameter and velocity distribution with increasing injection pressure up to 30 MPa, the elevated injection pressure on a jet break-up and atomization was characterized. Our experimental results show the existence of a leading edge of the jet observed at the initial stage of injection. This phenomenon revealed relatively large droplets ahead of the main jet then disappeared quickly as lose the droplets momentum. Furthermore, for all injection pressures, unique 'branch-like structure' was observed when the jet was fully developed. This structure had many counter rotating branches related to the effect of air-entrainment and rapidly broken down into droplet clusters and droplets. Especially, as increased injection pressure, the time to exhibit the structure and distance between two branches were decreased. In addition, based on the results of droplet diameter and velocity distribution at various injection pressures, we confirmed that the injection pressure plays a key role in droplet break-up, but a limit in injection pressure to enhance droplet break-up also occurred. That is, increasing injection pressure from 5 to 10 to 20 MPa led to a decrease in SMD (Sauter mean diameter) linearly by approximately 10 gm. However, an injection pressure above 20 MPa, did not result in any significant reduction in SMD. (C) 2013 Elsevier Inc. All rights reserved.

키워드

Gasoline direct injection (GDI)Phase Doppler particle analyzer (PDPA)Jet break-up processesBranch-like structureSauter mean diameter (SMD)Air-entrainmentGASOLINE
제목
Experimental study on spray break-up and atomization processes from GDI injector using high injection pressure up to 30 MPa
저자
Lee, SanghoonPark, Sungwook
DOI
10.1016/j.ijheatfluidflow.2013.11.005
발행일
2014-02
유형
Article
저널명
International Journal of Heat and Fluid Flow
45
1
페이지
14 ~ 22