냉수온도 변화에 따른 액체식 제습시스템의 성능에 관한 실험적 연구

An experimental study on the liquid desiccant system performance with various chilled water temperature

초록

This paper presents an experimental study of the liquid desiccant system performance. This liquid desiccant system wasconfigured with an air heat exchanger(copper tube) for controlling the sensible heat load of outdoor air and a honeycombmedia(wood fiber) for removing the moisture from outdoor air. By using the aqueous lithium chloride(LiCl) solution as desiccantworking fluid. Experiments were conducted the day of peak cooling load in the summer season when the outdoor air was hotand humid. Experiments result was evaluated on the dehumidification effectiveness while changed various chilled waterTemperature.

키워드

액체식 제습시스템염화리튬제습효율Liquid desiccnat systemLithium chloride(LiCl)Dehumidificationeffectiveness
제목
냉수온도 변화에 따른 액체식 제습시스템의 성능에 관한 실험적 연구
제목 (타언어)
An experimental study on the liquid desiccant system performance with various chilled water temperature
저자
박준영김민휘정재원
발행일
2013-10
유형
Proceeding
저널명
대한건축학회 추계학술발표대회논문집
33
2
페이지
309 ~ 310