상세 보기
여름철 플러쉬아웃 시행 시 제습 에너지비용에 관한 연구
- 이기용;
- 김주한;
- 박준석
초록
Newly constructed multi-residential buildings should be flushed out indoor contaminants after the completion of construction and prior to the occupancy by the Heath-friendly Housing Construction Standards. The flush-out performing standard recommends to maintain indoor relative humidity below 60% during the performing flush-out but it is hard to maintain recommended relative humidity because the weather of korea is a high humidity in summer. The scale of the domestic market being expanded not only built-in home appliance but also dehumidifier for a comfortable indoor environment in present. Therefore, this study calculate energy cost for dehumidification as calculated dehumidification performance by condition of performing flush-out when the flush-out performed by using dehumidifier. As a result, the amount of dehumidification for performing flush-out was estimated as maximum 20.5L/Day in Incheon City, and 19.4L/Day in Gwangju City. And it was also found that performing flush-out was lowest energy cost at 0.5ACH(14Days) than other air change rate.
키워드
- 제목
- 여름철 플러쉬아웃 시행 시 제습 에너지비용에 관한 연구
- 제목 (타언어)
- A Study on Energy Cost for Dehumidification on Performing Flush-out in Summer
- 저자
- 이기용; 김주한; 박준석
- 발행일
- 2016-04
- 유형
- Proceeding
- 저널명
- 대한건축학회 2016년도 춘계학술발표대회논문집
- 권
- 36
- 호
- 1
- 페이지
- 223 ~ 224