Effect on Critical Dimension Performance for Carbon Contamination of Extreme Ultraviolet Mask Using Coherent Scattering Microscopy and In-situ Contamination System

  • Doh, Jonggul
  • Lee, Sangsul
  • Lee, Jaewook
  • Hong, Seongchul
  • Jeong, Chang Young
  • ... Ahn, Jinho
  • 외 2명
Citations

WEB OF SCIENCE

4
Citations

SCOPUS

4

초록

The impact of carbon contamination on imaging performance was analyzed using an in-situ accelerated contamination system (ICS) combined with coherent scattering microscopy (CSM) which was installed at 11B extreme ultraviolet lithography (EUVL) beamline of the Pohang Accelerator Laboratory (PAL). The CSM/ICS is composed of CSM for measuring imaging properties and ICS for implementing acceleration of carbon contamination. The mask critical dimension (CD) and reflectivity were compared before and after carbon contamination through accelerated exposure. The reflectivity degradation was measured as 1.3, 2.0, and 2.8% after 1, 2, and 3 h exposure, respectively, due to carbon contamination of 5, 10, and 20 nm as measured by Zygo interferometer. The mask CD change for 88 nm line and space pattern was analyzed using CSM and a CD scanning electron microscope (SEM), and the result shows CD-SEM and CSM give large difference of 3.8 times in mask Delta CD after carbon contamination. This difference confirms the importance of using actinic inspection technique that employs exactly the same imaging condition as exposure tool.

키워드

CD PERFORMANCEEUV MASKLITHOGRAPHYRECONSTRUCTIONMODULUSOBJECT
제목
Effect on Critical Dimension Performance for Carbon Contamination of Extreme Ultraviolet Mask Using Coherent Scattering Microscopy and In-situ Contamination System
저자
Doh, JonggulLee, SangsulLee, JaewookHong, SeongchulJeong, Chang YoungLee, Dong GunKim, Seong-SueAhn, Jinho
DOI
10.1143/JJAP.51.06FB04
발행일
2012-06
유형
Article
저널명
Japanese Journal of Applied Physics
51
6
페이지