기둥의 길이변화에 따른 전이슬래브 시스템의 압축성능 평가

Evaluation on the Compression Capacity of Transfer Slab Systems according to the Variation of Column Length

초록

This paper presents compression capacity of transfer system in pilotis subjected to axial load. Recently, transfer system is usually used in low floors of wall-typed apartments when members’ sections are suddenly changed between upper walls and bottom columns. It can help transfer loads from the walls to the columns. Especially, a transfer girder system is usually used as one of transfer systems applied to a pilotis. However, the transfer girder system has low constructability and economics. Therefore, the other transfer system with transfer slab was suggested and has been studied. In this paper, to evaluate the compression capacity of transfer slab, tests were conducted on pilotis transfer slab systems subjected to axial load. First of all, two specimens were determined by FEM. The main parameter is length of the bottom columns. The lengh of the bottom columns were 40% and 50% of length of upper walls in the tranfer slab specimens. Results showed that the compression capacity of piloti transfer systems subjected to axial load was affected by length of bottom columns. The compression capacity is 52% higher than design strength for specimen with the bottom column’s length of 40% of length of the upper wall and 46% for specimen with the bottom column’s length of 50% of length of the upper wall.

키워드

전이시스템전이슬래브기둥의 길이축하중압축transfer systemtransfer slabcolumn’s lengthaxial laodcompression
제목
기둥의 길이변화에 따른 전이슬래브 시스템의 압축성능 평가
제목 (타언어)
Evaluation on the Compression Capacity of Transfer Slab Systems according to the Variation of Column Length
저자
심연주최창식
DOI
10.4334/JKCI.2016.28.6.695
발행일
2016-12
저널명
콘크리트학회 논문집
28
6
페이지
695 ~ 702