Isolated Acetabular Revision With Ceramic-on-Ceramic Bearings Using a Ceramic Head With a Metal Sleeve

Citations

WEB OF SCIENCE

12
Citations

SCOPUS

14

초록

The purpose of this study is to evaluate results of isolated acetabular revision with ceramic-on-ceramic bearings using a ceramic head with a metal sleeve. A retrospective review of fifty-three hips was performed. The mean patient age was 49.9 years and the mean follow-up period was 5.7 years. The mean modified Harris hip score improved from 47.5, pre-operatively, to 84.7 at the time of last follow-up (P < 0.001). Two patients reported squeaking of the hip. Three patients experienced loosening cup, necessitating re-revision surgery. There was a significant difference of acetabular bone defect between loose cup group and stable cup group (P = 0.018). There were no ceramic fractures and no osteolysis. The survival rate of the acetabular cup at the mid-term follow-up was 94.3%. In conclusion, ceramic head with a metal sleeve can be a reliable option for isolated acetabular revision.

키워드

hiprevision hip arthroplastyceramicmetal sleeveTOTAL HIP-ARTHROPLASTY11-YEAR FOLLOW-UPFEMORAL COMPONENTSWEARREPLACEMENTFAILUREOSTEOLYSISRETRIEVALMINIMUM
제목
Isolated Acetabular Revision With Ceramic-on-Ceramic Bearings Using a Ceramic Head With a Metal Sleeve
저자
Kim, YeesukKim, Young-HoHwang, Kyu-TaeChoi, Il-Yong
DOI
10.1016/j.arth.2014.03.007
발행일
2014-12
유형
Article
저널명
Journal of Arthroplasty
29
12
페이지
2420 ~ 2423