초록

: In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of 3 µm or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT)

키워드

Membrane Integrity TestPressure Decay TestLog Removal ValueUpper Control LimitDefect Types
제목
막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가
제목 (타언어)
Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring
저자
Kim, Jong-OhLee, Yong-SooKang, Ha-YoungKim, Hyung Soo
DOI
10.14579/MEMBRANE_JOURNAL.2017.27.3.248
발행일
2017-06
저널명
멤브레인
27
3
페이지
248 ~ 254

파일 다운로드