Effect of Hemodialysis on Peripapillary Choroidal Thickness Measured by Swept-Source Optical Coherence Tomography

Citations

WEB OF SCIENCE

7
Citations

SCOPUS

8

초록

Purpose: The aim was to investigate the effects of hemodialysis (HD) on peripapillary choroidal thickness (PCT) by swept-source optical coherence tomography and on other ophthalmologic parameters in patients with end-stage kidney disease. Materials and Methods: This was a prospective observational study. The authors evaluated 29 patients who underwent HD for end-stage kidney disease. Detailed ophthalmologic examinations and swept-source optical coherence tomography were performed immediately before and after HD. PCT was measured using the modification tool in the built-in OCT image viewer program. Changes in PCT before and after HD were statistically analyzed. Results: The average PCT significantly decreased from 127.3 +/- 49.2 mu m before HD to 117.1 +/- 50.9 mu m after HD (P<0.001). A significant correlation was found between changes in PCT and macular choroidal thickness (rho=0.547, P=0.002). Changes in mean ocular perfusion pressure did not significantly correlate with changes in PCT (rho=-0.049, P=0.803). Conclusions: PCT significantly decreased after HD. HD could influence the optic nerve head and its surrounding structures.

키워드

swept-source optical coherence tomographyhemodialysisperipapillary choroidal thicknessoptic nerve headend-stage kidney diseaseOCULAR PERFUSION-PRESSURECHRONIC KIDNEY-DISEASENORMAL-TENSION GLAUCOMAINTRAOCULAR-PRESSUREBLOOD-PRESSUREEYE DISEASESRISK-FACTORRETINANERVEFLUCTUATION
제목
Effect of Hemodialysis on Peripapillary Choroidal Thickness Measured by Swept-Source Optical Coherence Tomography
저자
Lee, Won JuneHong, RimkyungKang, Min HoCho, HeeyoonHan, Sang-WoongYi, Joo-HarkShin, Yong UnSeong, Mincheol
DOI
10.1097/IJG.0000000000001762
발행일
2021-06
유형
Article
저널명
Journal of Glaucoma
30
6
페이지
459 ~ 464