상세 보기
TMD가 설치된 구조물의 태풍거동 분석
- 김홍진;
- 최선영;
- 조성우;
- 황재승;
- 유은종
초록
The wind response and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse wind load estimation. The TMD was installed on a 39-story, 184.6m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet-based data logging system. On Sep. 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. In order to analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated.
키워드
- 제목
- TMD가 설치된 구조물의 태풍거동 분석
- 제목 (타언어)
- Wind Response Monitoring of a Building with TMD
- 저자
- 김홍진; 최선영; 조성우; 황재승; 유은종
- 발행일
- 2011-12
- 저널명
- 대한건축학회논문집 구조계
- 권
- 27
- 호
- 12
- 페이지
- 83 ~ 90