상세 보기
초록
The current subjective system of classifying floor impact sound levels is insufficient and requires more accurate classification criteria Statements describing floor impact sound are collected and used to create a new statement-based scale using the equal-appearing interval scale method. An auditory experiment was conducted measuring annoyance levels and using the new statement scale to establish a floor impact noise standard in apartment buildings. Floor impact sounds from impact ball were re-corded; the impact sound pressure level (SPL) and the temporal decay rate (DR) were analyzed. For the experiment, A-weighted exposure levels of the heavyweight floor impact sounds ranging from 34 to 73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale (annoyance level) and the new 7-pt statement scale. Consequently, a floor impact sound classification based on re-sponse statement was proposed.
키워드
- 제목
- 중량충격음 등급화를 위한 생활감 평가
- 제목 (타언어)
- Psychoacoustical Evaluation for Heavy-weight impact sound Classification
- 저자
- 김성민; 홍주영; 전진용
- 발행일
- 2015-04
- 유형
- Proceeding
- 저널명
- 한국소음진동공학회 2015년 춘계학술대회논문집
- 페이지
- 689 ~ 691