The ultrasonic nonlinear parameter β is generally known as an effective parameter for evaluating material degradation. Thus far, most research has been conducted using a contact method. However, since measurement by this contact method is affected by the contact conditions between the transducer and the specimen, additional devices are required to maintain the contact conditions stable during the measurement. To avoid this inconvenience, this paper proposes a noncontact method. In this study, only the receiver was replaced with a noncontact receiver, and then, the ultrasonic nonlinear parameters measured by the newly developed noncontact receiver were compared with those measured by the contact receiver. Results obtained using both these receivers for heat-treated aluminum alloy specimens showed good agreement. From this result, we can confirm that the ultrasonic nonlinear parameter β can be measured using the proposed noncontact ultrasonic method.
키워드
- 제목
- 비접촉식 초음파 수신기를 이용한 초음파 비선형성 측정
- 제목 (타언어)
- Measurement of ultrasonic nonlinear parameter by using non-contact ultrasonic receiver
- 저자
- Kim, Jongbeom; Jhang, Kyung-Young
- 발행일
- 2014-10
- 유형
- Article
- 저널명
- 대한기계학회논문집 A
- 권
- 38
- 호
- 10
- 페이지
- 1133 ~ 1137