The city of Seoul will limit the maximum particulate matter (PM10) concentration to <= 35 mu g/m(3) (from 2024). Herein, a numerical parametric study was conducted on the PM removal efficiency of the heating, ventilation, and air conditioning (HVAC) filters installed in the ceiling of subway cabins. The PM10 concentration distribution was explored according to the flow rate and flow rate ratio of the air introduced into the cabin. Under the current ventilation conditions of the subway train HVAC system, the PM10 concentration was highest in the cabin central area where exhaust outlets are located and decreased toward both ends of the cabin. The indoor airflow was improved and the PM10 concentration was reduced by increasing the flow rate of the supplied air at both ends of the cabin while decreasing it in the central area. It was found that the strengthened PM10 concentration criterion of Seoul can be met by increasing the ventilation flow rate to 700 CMH (currently, 500 CMH) and the filter efficiency to 85% (currently, 70%) while maintaining the current flow rate ratio. These results are expected to be used as important reference data for reducing the PM concentration in subway cabins and thereby improving indoor air quality.

키워드

subway cabinPM10HVACfilter efficiencyindoor air qualityAIR-FLOWCFDMODEL
제목
Study on the Ventilation Method to Maintain the PM10 Concentration in a Subway Cabin below 35 mu g/m(3)
저자
Choi, Eun-SeoYook, Se-JinKim, MinjeongPark, Duckshin
DOI
10.3390/toxics10100560
발행일
2022-10
유형
Article
저널명
TOXICS
10
10
페이지
1 ~ 16

파일 다운로드