상세 보기
Characteristics of a Micro-pattern Gas Detector with Pixel Read-out for X-ray Imaging
- Lee, Dong Hoon;
- Kim, Bonghoe;
- Jeon, Sungchae;
- Shin, Ki Young;
- Cha, Bokyung;
- ... Kim, Yong Kyun;
- 외 1명
WEB OF SCIENCE
0SCOPUS
0초록
A micro-pattern gas detector (MPGD) with a pixel read out was evaluated for X-ray imaging. Our MPGD has one gas electron multiplier (GEM) with an active area of 5 x 5 cm(2) as a charge amplifying stage that is completely decoupled from the readout electrode, and we have used an advanced printed-circuit board (PCB) technique to fabricate the micro-pattern readout. A test chamber was fabricated for our experiment, and all components of our MPGD were assembled in a test chamber filled gas. We studied the charge signal by X-ray used for a medical diagnostic system in the pixel readout with a gas mixtures of Xe (90%)/CO(2) (10%) and the performance of our MPGD was examined with an X-ray energy and various applied voltages of the GEM and the drift plate.
키워드
- 제목
- Characteristics of a Micro-pattern Gas Detector with Pixel Read-out for X-ray Imaging
- 저자
- Lee, Dong Hoon; Kim, Bonghoe; Jeon, Sungchae; Shin, Ki Young; Cha, Bokyung; Seo, Changwoo; Kim, Yong Kyun
- 발행일
- 2011-12
- 유형
- Article
- 권
- 59
- 호
- 6
- 페이지
- 3666 ~ 3669