Three-Dimensional Quantitative Assessment of Pedicle Screw Accuracy in Clinical Utilization of a New Robotic System in Spine Surgery A Multicenter Study

  • Ha, Byeong-Jin
  • Lee, Jong-Min
  • Yoon, Seon-Jin
  • Kim, Byung-Kwan
  • Lee, Junseok
  • 외 12명
Citations

WEB OF SCIENCE

13
Citations

SCOPUS

15

초록

Objective: The objective of this study was to evaluate the accuracy of pedicle screw placement in patients undergoing percutaneous pedicle screw fixation with robotic guidance, using a newly developed 3-dimensional quantitative measurement system. The study also aimed to assess the clinical feasibility of the robotic system in the field of spinal surgery.Methods: A total of 113 patients underwent pedicle screw insertion using the CUVIS-spine pedicle screw guide system (CUREXO Inc.). Intraoperative O-arm images were obtained, and screw insertion pathways were planned accordingly. Image registration was performed using paired-point registration and iterative closest point methods. The accuracy of the robotic-guided pedicle screw insertion was assessed using 3-dimensional offset calculation and the Gertzbein-Robbins system (GRS).Results: A total of 448 screws were inserted in the 113 patients. The image registration success rate was 95.16%. The average error of entry offset was 2.86 mm, target offset was 2.48 mm, depth offset was 1.99 mm, and angular offset was 3.07 degrees. According to the GRS grading system, 88.39% of the screws were classified as grade A, 9.60% as grade B, 1.56% as grade C, 0.22% as grade D, and 0.22% as grade E. Clinically acceptable screws (GRS grade A or B) accounted for 97.54% of the total, with no reported neurologic complications. Conclusion: Our study demonstrated that pedicle screw insertion using the novel robot -assisted navigation method is both accurate and safe. Further prospective studies are necessary to explore the potential benefits of this robot-assisted technique in comparison to conventional approaches.

키워드

Robot-assisted spine surgeryPedicle screwsDimensional measurement accuracyRADIATION-EXPOSUREPLACEMENTLUMBAR
제목
Three-Dimensional Quantitative Assessment of Pedicle Screw Accuracy in Clinical Utilization of a New Robotic System in Spine Surgery A Multicenter Study
저자
Ha, Byeong-JinLee, Jong-MinYoon, Seon-JinKim, Byung-KwanLee, JunseokLee, Su hunRyu, SeungjaeCha, YongyeobHwang, SungteacWoo, DonggiLee, Chang KyuShin, Dong AhHa, YoonKuh, Sung UkKim, Keung NyunSon, DongwukYi, Seong
DOI
10.14245/ns.2346552.276
발행일
2023-09
유형
Article
저널명
NEUROSPINE
20
3
페이지
1028 ~ 1039

파일 다운로드