반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능평가

Evaluation on Anchorage Performance of 57mm Headed Bars in Exterior Beam-Column Joint under Cyclic loading

초록

In this study, the anchoring performance of 57mm headed bars anchored at the external beam-column joint under cyclic loading was evaluated. A total of 6 external beam-column joint test specimens were planned, and anchorage performance was evaluated by setting concrete compressive strength, side covering thickness, lateral reinforcement ratio, and fracture type as major experimental variables. As result of cyclic loading test, it was found that the factors that had the greatest influence on the anchoring capacity of the large-diameter headed bar anchored at the joint were the side cover thickness and the transverse reinforcing bar. It was confirmed that the 57mm large-diameter headed bar anchored at the external beam-column joint showed sufficient anchoring capacity even under cyclic loading.

키워드

확대머리철근대구경 철근정착성능외부 보-기둥 접합부반복하중Headed barLarge diameter steel barAnchorage CapacityExternal beam-column jointCyclic loading
제목
반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능평가
제목 (타언어)
Evaluation on Anchorage Performance of 57mm Headed Bars in Exterior Beam-Column Joint under Cyclic loading
저자
정형석정주홍최창식배백일최현기
DOI
10.11112/jksmi.2021.25.6.68
발행일
2021-12
저널명
한국구조물진단유지관리공학회 논문집
25
6
페이지
68 ~ 75

파일 다운로드