Comparison of the GlideScope and the McGrath method using vascular forceps and a tube exchanger in cases of simulated difficult airway intubation

Citations

SCOPUS

5

초록

Background A "difficult airway" can be simulated with an extrication collar, which restricts cervical motion and mouth opening. The purpose of this study is to compare the efficacy of the GlideScope and the McGrath in difficult airway simulation. Methods Patients were randomized using computer-generated numbers and were placed into the GlideScope group or the McGrath group. The total intubation time was defined as the time measured from when the anesthesiologist picks up the device to the time at which three successive end-tidal CO2 values are acquired after intubation. Results There was no significant difference in total intubation time between the two groups (73.0 ± 25.3 sec vs. 72.3 ± 20.9 sec, P = 0.92). The success rates of the first intubation attempt did not differ between the two groups (82.8% vs. 83.3%, P = 0.95). Conclusions Our results suggest that there are no significant differences in the intubations with GlideScope and McGrath using vascular forceps and tube exchangers in difficult intubation scenarios.

키워드

Airway managementIntratracheal intubationLaryngoscopesRANDOMIZED CONTROLLED-TRIALTRACHEAL INTUBATIONANESTHETIZED PATIENTSSTYLETVIDEOLARYNGOSCOPE
제목
Comparison of the GlideScope and the McGrath method using vascular forceps and a tube exchanger in cases of simulated difficult airway intubation
저자
Shim, Jae-HangJeon, Woo JaeCho, Sang YunChoe, Gyu Ho
DOI
10.4097/kjae.2016.69.2.133
발행일
2016-04
유형
Article
저널명
Korean Journal of Anesthesiology
69
2
페이지
133 ~ 137

파일 다운로드