겹침이음 길이가 짧은 RC 기둥의 이방향 횡하중 가력 실험

Bidirectional Lateral Loading of RC Columns with Short Lap Splices

초록

Reinforced concrete (RC) buildings built in the 1980s are vulnerable to seismic behavior because they were designed without any consideration of seismic loads. These buildings have widely spaced transverse reinforcements and a short lap splice length of longitudinal reinforcements, which makes them vulnerable to severe damage or even collapse during earthquakes. The purpose of this study is to investigate the impact of bidirectional lateral loads on RC columns with deficient reinforcement details. An experimental test was conducted for two full-scale RC column specimens. The test results of deficient RC columns revealed that bidirectional loading deteriorates the seismic capacity when compared with a column tested unidirectionally. Modeling parameters were extracted from the tested load-displacement response and compared with those proposed in performance-based design standards. The modeling parameters proposed in the standards underestimated the deformation capacity of tested specimens by nearly 50% and overestimated the strength capacity by 15 to 20%.

키워드

Bidirectional loadingModeling parameterLap spliceRC column
제목
겹침이음 길이가 짧은 RC 기둥의 이방향 횡하중 가력 실험
제목 (타언어)
Bidirectional Lateral Loading of RC Columns with Short Lap Splices
저자
이창석박이슬한상환
DOI
10.5000/EESK.2020.24.1.019
발행일
2020-01
저널명
한국지진공학회논문집
24
1
페이지
19 ~ 27