초록

The sources of greenhouse gases (GHG) at Hanyang University Ansan campus, including direct sources, indirect sources, and others, were investigated in order to establish the GHG inventory. Emission of GHG was calculated with the energy use from each source from 2007 and 2009. The indirect emission (56.7%) due to the electricity significantly contributed to total GHG emission. The scenario for the GHG reduction was designed for both campus administration and members. The reduction potential of GHG was simulated from 2007 to 2020 using Long-range Energy Alternatives Planning (LEAP) model. In case of GHG reduction scenario by campus administration, the GHG can be reduced by 63.34 ton CO2eq/yr for stationary combustion in the direct source, by 221.1 ton CO2eq/yr for mobile combustion in the direct source, and by 4,637.34 ton CO2eq/yr for lighting in the indirect source, compared to 2020 Business As Usual (BAU). In case of GHG reduction action scenario by campus members, the reduction potential of GHG was 1293.76 ton CO2eq/yr. Overall, the total GHG emissions in 2020 by the both scenarios can be decreased by 24% compared to 2020 BAU.

키워드

온실가스 배출량온실가스 잠재량LEAP 모델Greenhouse Gases EmissionGreenhouse Gases Reduction PotentialLong-Rage Energy Alternatives Planning (LEAP) Model
제목
LEAP 모델 적용을 통한 대학단위 온실가스 감축안 도출 - 한양대학교 안산캠퍼스 대상으로
제목 (타언어)
Greenhouse Gas Reduction Scenario from LEAP Model Application to a University Campus-For Hanyang University Ansan Campus
저자
박효정정혜진이승묵박재우
DOI
10.4491/KSEE.2012.34.4.280
발행일
2012-04
저널명
대한환경공학회지
34
4
페이지
280 ~ 287