상세 보기
부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석
- 이문성;
- 최윤철;
- 임재형;
- 문정호;
- 최창식
초록
Post-tensioned precast concrete system (PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with the topping concrete on the PC shell beam and post-tensioning. Nonlinear analysis was conducted, using ANSYS, a finite-element analysis program, to obtain data for determining the characteristics of the structure and to allow various parametric analyses for post-tensioned wide beam-column connections. In this analysis, the Solid 65 element was used, in which concrete element had 8 nodes and each node had 3 degrees of freedomIn. Solid 65, the shear-transfer factor reflects a decrease of shear strength for the positions with cracks, as an impact factor to make the analysis value approximate the experiment value. In this study, the behavior of test specineus were most closely predicted to the experimental results, when the shear-transfer coefficient 0.85 was used for a closed crack, and 0.2 was used for an open crack.
키워드
- 제목
- 부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석
- 제목 (타언어)
- FE Analysis of Exterior Wide Beam-Column Connectionswith Bonded Tendon Stress
- 저자
- 이문성; 최윤철; 임재형; 문정호; 최창식
- 발행일
- 2008-08
- 저널명
- 한국전산구조공학회논문집
- 권
- 21
- 호
- 4
- 페이지
- 307 ~ 315