Investigation of radiative and convective heat transfer in storage vaults for improving space efficiency

Citations

WEB OF SCIENCE

4
Citations

SCOPUS

3

초록

We used computational analysis in order to study the cooling effects of the cylindrical tubes located inside a storage vault for spent nuclear fuel. We considered the effects of the radiative and convective heat transfer on the cooling of the cylindrical tubes based on the non-dimensional maximum permissible surface temperature. We also identified the factors that affect the cooling of cylindrical tubes by investigating the cooling effects with the same heat source as a function of the distance between the tubes, the entrance length, and the tube arrangement. The thermal performance, characteristics indicated that a non-uniform staggered tube array could be used in order to improve the storage efficiency of a vault in comparison to the reference uniform in-line tube arrangement, while maintaining the tube surface temperatures at a value below the maximum permissible temperature.

키워드

RadiationCombined convectionCR ratioCooling effectNon-uniform tube arrangementCROSS-FLOWFORCED-CONVECTION
제목
Investigation of radiative and convective heat transfer in storage vaults for improving space efficiency
저자
Kim, DongheeYook, Se-JinLee, Kwan-Soo
DOI
10.1016/j.ijheatmasstransfer.2014.09.026
발행일
2015-01
유형
Article
저널명
International Journal of Heat and Mass Transfer
80
페이지
301 ~ 308