상세 보기
Modeling of a monopolar ion-exchange membrane for nutrient salts removal
- Kang, Seoktae;
- Chae, So-Ryong;
- Jang, Am;
- Kim, Jong-Oh
WEB OF SCIENCE
3SCOPUS
3초록
Mathematical model was developed to determine reliable design conditions of electrodialysis (ED) system with a monopolar ion-exchange membrane and assess its performance. Good agreement was obtained between the simulated results of the mathematical model and the measured data. Removal of nitrogenous ions of NH (Formula presented.) -N was easier than that of PO (Formula presented.) -P ions because of high mobility due to the small molecular weight. The supplied voltage (E) and the concentration ratio of concentrate to dilute (k) were important controlling factors for the removal rate of nutrient salts (Si). From the experimental and simulated results, it is believed that the developed model is applicable to the flow analysis of ED system.
키워드
- 제목
- Modeling of a monopolar ion-exchange membrane for nutrient salts removal
- 저자
- Kang, Seoktae; Chae, So-Ryong; Jang, Am; Kim, Jong-Oh
- 발행일
- 2015-03
- 유형
- Article
- 권
- 53
- 호
- 10
- 페이지
- 2825 ~ 2830