The objective of this research is to evaluate of global and local damage for steel-concrete composite structures under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed transient nonlinear thermal structure interaction(TSI) parallel fire analysis method is implemented in ANSYS. To validate the TSI parallel fire analysis method, a comparison is made with the standard fire test results. The proposed TSI parallel fire analysis method is applied to fire damage analysis and performance evaluation for Buchen highway bridge. The result of analysis, temperature of low flange and web are exceed the critical temperature. The deflection and deformation state show good agreement with the fire accident of buchen highway bridge.
키워드
- 제목
- 화재에 노출된 교량하부 강합성 구조물에 대한열-구조 연성 병렬화재해석
- 제목 (타언어)
- Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading
- 저자
- 윤성환; 길흥배; 이일근; 김우석; 박대효
- 발행일
- 2013-08
- 저널명
- 한국전산구조공학회논문집
- 권
- 26
- 호
- 4
- 페이지
- 283 ~ 292