Detection of cavities around concrete sewage pipelines using impact-echo method

Citations

WEB OF SCIENCE

31
Citations

SCOPUS

37

초록

Impact-echo method has been successfully used to detect flaws in concrete and to evaluate the state of grout bonding in tunnels. It has not yet been used to detect underground cavities formed by leakage of pipelines, which is becoming a major problem in many urban environments. We perform model and field tests to evaluate whether the impact-echo method can be used to detect cavities around concrete sewage pipelines. Fourier spectrum was used to determine the resonant frequency and the short time Fourier transform was used to determine the temporal variation of the resonant frequency component. Results show that the presence of cavity cannot be reliably predicted from the wave time history or Fourier spectrum. The spectrogram is demonstrated to be a better indicator for detecting the presence of a cavity. The cavity induces a longer tail in the spectrogram because of a higher impedance contrast and a lower attenuation. We propose a new quantitative index based on the resonant frequency and the spectrogram, denoted as the sustained duration. Both model and field tests demonstrate that the cavity in wet soils can be successfully detected using the proposed index.

키워드

Impact-echoCavitySewage pipelineSustained durationTRANSIENT-RESPONSE
제목
Detection of cavities around concrete sewage pipelines using impact-echo method
저자
Kang, Jae MoSong, SeokminPark, DuheeChoi, Changho
DOI
10.1016/j.tust.2017.02.002
발행일
2017-05
유형
Article
저널명
Tunnelling and Underground Space Technology
65
페이지
1 ~ 11