직접전단 시험을 통한 분리타설된 강섬유 보강 콘크리트의 전단마찰강도 분석

Analysis of Shear Friction Strength of Separated Steel Fiber Reinforced Concrete under Direct Shear Test
Citations

SCOPUS

0

초록

When precast concrete elements and cast-in-place concrete are formed separately, they create shear friction at their interface. Ensuring structural integrity is vital, and this involves placing shear friction reinforcement at this interface. Steel fibers are recognized for enhancing shear strength by leveraging the dowel action of shear friction reinforcements, and shear friction capacity can be improved by using steel fibers locally. In this study, 12 push-off tests were conducted to assess how steel fiber reinforced concrete (SFRC) contributes to shear friction strength in direct shear. The experimental findings were also compared with the predicted values from current code provisions. These experiments revealed that the crack width at maximum shear friction strength increased as the volume of steel fibers increased, and the contribution of concrete also increased with higher steel fiber volume. Notably, Eurocode 2 yielded higher contributions compared to AASHTO LRFD. Eurocode 2, which takes into account concrete's tensile strength, provided the most accurate results. Therefore, future studies should consider the influence of concrete when designing for shear friction strength.

키워드

precast concreteshear frictionsteel fiber reinforced concrete프리캐스트 콘크리트전단마찰강섬유 보강 콘크리트
제목
직접전단 시험을 통한 분리타설된 강섬유 보강 콘크리트의 전단마찰강도 분석
제목 (타언어)
Analysis of Shear Friction Strength of Separated Steel Fiber Reinforced Concrete under Direct Shear Test
저자
Lee, Hye-WonSon, Dong-HeeBae, Baek-IlChoi, Chang-Sik
DOI
10.5659/JAIK.2023.39.10.243
발행일
2023-10
유형
Article
저널명
대한건축학회논문집
39
10
페이지
243 ~ 250