Improvement in the pitting resistance of Inconel-600 by nitrogen ions implantation

  • Afzal, Naveed
  • Deen, Kashif Mairaj
  • Ahmad, Riaz
  • Niazi, Zahra
  • Farooq, Ameeq
  • 외 3명
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

4

초록

The surface of Ni-Cr-Fe (Inconel-600) alloy was modified by implanting 500 keV nitrogen ions at room temperature using pelletron accelerator to dose of 1.87 x 10(14) ions/cm(2). X-ray diffraction analysis of the ions implanted samples indicated the formation of Cr2N phase. Electrochemical testing of Inconel-600 alloy before and after the ions implantation was conducted using potentiodynamic tafel scan, potentiodynamic anodic polarization and electrochemical impedance spectroscopy techniques in an acidic saline solution. The higher anodic polarization slope (beta(a)), low cathodic polarization slope (beta(c)) and decrease in corrosion current density after ions implantation were attributed to the modification of passive film by the nitrogen ions. The scanning electron microscopy and electrochemical analyses of the ions implanted samples revealed an improvement in the pitting resistance of the alloy.

키워드

STRESS-CORROSION CRACKINGCHLORIDE SOLUTIONSLOW-TEMPERATUREALLOY 600SUPERALLOYSBEHAVIORKINETICSSTEELWATER
제목
Improvement in the pitting resistance of Inconel-600 by nitrogen ions implantation
저자
Afzal, NaveedDeen, Kashif MairajAhmad, Riaz Niazi, ZahraFarooq, AmeeqRafique, MohsinKim, Yong-SooKhaleeq-ur-Rahman, Muhammad
DOI
10.1134/S207020511503003X
발행일
2015-05
유형
Article
저널명
Protection of Metals and Physical Chemistry of Surfaces
51
3
페이지
481 ~ 485