A shutdown dose rates analysis of the Korean fusion demonstration reactor using MCNP5 mesh-based R2S approach

  • Kim, Jae Hyun
  • Woo, Myeong Hyeon
  • Shin, Chang Ho
  • Hong, Ser Gi
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

5

초록

In the fusion reactor, lots of high energy neutrons are produced by the nuclear fusion reaction, which produces unstable nuclides emitting gamma rays in various components of fusion energy systems. So, estimation of shut down dose rate in such facilities is very important to check if the dose rates are below the radiational safety limits. Generally, two computational analysis schemes of the cell-based Rigorous-2-Step (R2S) method and the Direct-1-Step (D1S) method have been used widely in evaluating the shutdown dose rates. In this work, the mesh-based R2S method is automated with in-house auxiliary programs for our practical applications. This mesh-based R2S procedure was applied to the Korean fusion demonstration reactor (K-DEMO) facility. From the analysis for K-DEMO, it was shown that the automated mesh-based R2S procedure gives much higher computational efficiencies in terms of FOM than the cell-based R2S method and gives higher shutdown dose rates than the cell-based R2S and D1S method.

키워드

K-DEMOMesh-based R2S methodShutdown dose rateApplication programsGamma raysThermonuclear reactionsCell-basedComputational analysisD1S methodDemonstration reactorFusion energy systemsHigh-energy neutronR2S methodSafety limitsMesh generation
제목
A shutdown dose rates analysis of the Korean fusion demonstration reactor using MCNP5 mesh-based R2S approach
저자
Kim, Jae HyunWoo, Myeong HyeonShin, Chang HoHong, Ser Gi
DOI
10.1016/j.fusengdes.2021.112321
발행일
2021-06
유형
Article
저널명
Fusion Engineering and Design
167
페이지
1 ~ 9