상세 보기
Cyclic Performance of Welded Unreinforced Flange-Welded Web Moment Connections
- Han, Sang Whan;
- Moon, Ki Hoon;
- Jung, Jin
Citations
WEB OF SCIENCE
17Citations
SCOPUS
21초록
The welded unreinforced flange-welded web (WUF-W) moment connection is a prequalified connection for the special moment frame (SMF) specified in AISC 358-10. In this study, inelastic cyclic tests of four WUF-W specimens were conducted to evaluate the seismic performance of WUF-W connections with different beam depths and panel zone strength ratios. The specimens were made to satisfy the design and detailing criteria specified in AISC 341-10 and AISC 358-10. Test results showed that the WUF-W connections with a beam depth of 692 mm passed the acceptance criteria required for SMF connections, whereas the WUF-W connections with a beam depth of 890 mm did not meet the criteria.
키워드
BEHAVIOR; DETAILS; TESTS
- 제목
- Cyclic Performance of Welded Unreinforced Flange-Welded Web Moment Connections
- 저자
- Han, Sang Whan; Moon, Ki Hoon; Jung, Jin
- 발행일
- 2014-11
- 유형
- Article
- 권
- 30
- 호
- 4
- 페이지
- 1663 ~ 1681