A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

Citations

WEB OF SCIENCE

3
Citations

SCOPUS

6

초록

In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

키워드

Grid-connected inverterCompensator designSecond-order harmonic currentDynamic responsePOWER-CONDITIONING SYSTEMCURRENT RIPPLE REDUCTIONINPUT
제목
A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter
저자
Jung, Hong-JuKim, Rae-Young
DOI
10.5370/JEET.2014.9.6.1988
발행일
2014-11
유형
Article
저널명
Journal of Electrical Engineering & Technology
9
6
페이지
1988 ~ 1994