Startup Failure Detection Method for Hydrogen Recirculation Blower Under Cold Start Conditions

  • Lee, Neulpureunhaneul
  • Oh, Eun-Sol
  • Lee, Hyun-Jun
  • Yoo, Sung-Jin
  • Yoon, Young-Doo
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

This paper proposes a method to detect startup failure caused by ice formation on the motor in sensorless control systems. The sensorless control strategy adopted in this study estimates the rotor position by determining the initial rotor angle and initiates motor operation based on a model-based sensorless control scheme. However, under cold start conditions, startup failure may occur when the torque required to overcome the ice exceeds the maximum torque capability of the motor. Therefore, a startup failure detection mechanism is essential during the initial operation phase. This paper proposes a detection method for startup failure, which is based on the error ratio between electrical energy and mechanical energy. The effectiveness of the proposed method is experimentally validated.

키워드

Cold startuphydrogen recirculation blower (HRB)permanent-magnet (PM) motorsensorless drivestartup failure detectionSENSORLESS CONTROLPOSITIONOBSERVERMODEL
제목
Startup Failure Detection Method for Hydrogen Recirculation Blower Under Cold Start Conditions
저자
Lee, NeulpureunhaneulOh, Eun-SolLee, Hyun-JunYoo, Sung-JinYoon, Young-Doo
DOI
10.1109/ECCE58356.2025.11260083
발행일
2025-12
유형
Conference paper
저널명
2025 IEEE Energy Conversion Conference Congress and Exposition, ECCE 2025
페이지
1 ~ 6