Time of Flight System for MeV Neutron

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

2

초록

The fast neutron facility with a prototype detecting system at the Korea Institute of Geoscience and Mineral Resources (KIGAM) was constructed in 2007. The detecting system was upgraded by changing the detecting sensor and its size and by changing the distance from the detector to the neutron target. The H-3(p,n)He-3 reaction with a Ti-H-3 target was used to estimate the time resolution of the upgraded system. The time resolution of the system was observed to be 36 keV (1.79 ns) at 2.077 MeV by analyzing the absorption width of the neutron energy spectrum for C-12. The main factor for the time resolution of the system is thought to be a variation in the repetition time of the bunching beam. The width of the neutron energy spectrum was 150 keV, which corresponded to the proton energy loss caused by a Ti thickness of 2 mg/cm(2) (4.44 mu m) oil the Ti-H-3 target. The neutron total cross sections for C-12 and Si-28 were measured by using the upgraded detecting system and the results are compared with the data for Evaluated Nuclear Data File-VI (ENDF-VI).

키워드

TOF systemTotal cross sectionMeV NeutronC-12Si-28H-3(p,n)He-3
제목
Time of Flight System for MeV Neutron
저자
Kim, Gi-DongChoi, Hyung WoocWoo, Hyun-JungKim, Yong Kyun
DOI
10.3938/jkps.54.1465
발행일
2009-04
유형
Article
저널명
Journal of the Korean Physical Society
54
4
페이지
1465 ~ 1469