Punching shear design method of voided slabs

Citations

SCOPUS

0

초록

This study presents punching shear design method of voided slab in accordance with arrangement of voids around columns. According to previous studies, the slab-column connection of voided slabs is weaker than that of the solid slab due to the lack of cross-sectional area of concrete by voids. In this study, it is assumed that the arrangement of voids exert influence on the punching shear strength of voided slabs. To verify the assumption, finite element analysis was conducted related with previous test results. The variable of FE analysis was a distance between voids and column face. Based on FE analysis and test results including previous studies, punching shear design method is suggested which can consider the arrangement of voids around columns. The suggested design method is based on the punching shear design method in ACI-318. As a result, it can predict the punching shear strength of voided slabs according to arrangement of voids around column.

키워드

Design methodFinite element analytical studyPunching shearVoided slabFinite element methodAnalytical studiesCross sectional areaDesign methodPunching shearPunching shear strengthSlab-column connectionSolid slabsVoided slabDesign
제목
Punching shear design method of voided slabs
저자
Chung, Joo HongChoi, Hyun KiChoi, Chang SikJung, Hyung Suk
DOI
10.4028/www.scientific.net/KEM.754.333
발행일
2017-07
유형
Conference Paper
저널명
Key Engineering Materials
754 KEM
페이지
333 ~ 336