상세 보기
Inter-Turn Fault Diagnosis of Induction Motors Based on Current Vector Pattern Analysis in Stationary Coordinate Frame
- Yun, Inyeol;
- Kim, Hyunwoo;
- Lee, Ju;
- Lee, Sung-Gu
WEB OF SCIENCE
2SCOPUS
3초록
In this study, a current vector pattern is analyzed for inter-turn fault (ITF) diagnosis of induction machines (IMs), and an ITF diagnosis algorithm is proposed. When an ITF occurs in IMs, a negative-sequence current is generated due to fault resistance, even though a positive-sequence voltage is applied to IMs. Based on the mathematical model of IMs with an ITF, the current vector patterns in the stationary coordinate frame are analyzed. The superposition of positive- and negative-sequence components results in an elliptical current vector trajectory, and its orientation varies depending on the fault conditions. The co-simulation using finite element analysis and circuit simulation is implemented to analyze the current vector pattern of IMs with an ITF. The ITF diagnosis is proposed based on the current vector pattern. A 12 kW, four-pole, three-phase IM and terminal box, which was used to implement an ITF, is manufactured, and an experiment setup is established to verify the ITF algorithm. The effectiveness of the proposed ITF algorithm is validated through experimental verification of the manufactured IM and terminal box.
키워드
- 제목
- Inter-Turn Fault Diagnosis of Induction Motors Based on Current Vector Pattern Analysis in Stationary Coordinate Frame
- 저자
- Yun, Inyeol; Kim, Hyunwoo; Lee, Ju; Lee, Sung-Gu
- 발행일
- 2025-07
- 유형
- Article
- 저널명
- APPLIED SCIENCES-BASEL
- 권
- 15
- 호
- 15
- 페이지
- 1 ~ 15