초록

We developed whole-body exposure systems for in-vivo study at cellular (848.5 MHz) and Personal Communication System (PCS, 1,762.5 MHz) frequency, utilizing reverberation chamber. The field uniformities in the test area of the designed chambers were verified by simulation and measurement. In the whole-body exposure environment, Specific Absorption Rate (SAR) distributions inside of mice were calculated using Finite Difference Time Domain (FDTD) simulation. Key results are presented in this article.