상세 보기
초록
In this paper, a headset multiple-input multiple-output(MIMO) antenna for on-body application is proposed and the antenna performance with body effect and the impact on human body are investigated. The proposed MIMO antenna is composed of two planar inverted-F antennas(PIFA) above ground plane and an isolator located between the two antennas enhance the isolation characteristic. Simulation was carried to analyze the effect of human body on antenna performance when a human body is located in the near field of the antenna. According to the measurement result, the diversity performance of the proposed antenna can be considered good since ECC(Envelope Correlation Coefficient), which commonly indicates the performance of a MIMO antenna, remains below 0.1 over the ISM band. The measured SAR values for antennas 1 and 2 are 0.575 W/kg and 0.571 W/kg, respectively when 250 mW input power in engaged. These values satisfy the FCC guideline which states that the 1-g average SAR should be lower than 1.6 W/kg.
키워드
- 제목
- 인체부착형 Headset MIMO 안테나 설계
- 제목 (타언어)
- Design of Headset MIMO Antenna for On-Body Application
- 저자
- 김성진; 김동호; 권결; 최재훈
- 발행일
- 2011-12
- 저널명
- 한국전자파학회 논문지
- 권
- 22
- 호
- 12
- 페이지
- 1107 ~ 1115