상세 보기
비연성 철근콘크리트 건물의 내진설계범주에 따른 붕괴 위험성 평가
- 김민지;
- 한상환;
- 김태오
초록
Existing old reinforced concrete buildings could be vulnerable to earthquakes because they were constructed without satisfying seismic design and detail requirements. In current seismic design standards, the target collapse probability for a given Maximum Considered Earthquake (MCE) ground-shaking hazard is defined as 10% for ordinary buildings. This study aims to estimate the collapse probabilities of a three-story, old, reinforced concrete building designed by only considering gravity loads. Four different seismic design categories (SDC), A, B, C, and D, are considered. This study reveals that the RC building located in the SDC A region satisfies the target collapse probability. However, buildings located in SDC B, C, and D regions do not meet the target collapse probability. Since the degree of exceedance of the target probability increases with an increase in the SDC level, it is imminent to retrofit non-ductile RC buildings similar to the model building. It can be confirmed that repair and reinforcement of old reinforced concrete buildings are required.
키워드
- 제목
- 비연성 철근콘크리트 건물의 내진설계범주에 따른 붕괴 위험성 평가
- 제목 (타언어)
- Seismic Collapse Risk for Non-Ductile Reinforced Concrete Buildings According to Seismic Design Categories
- 저자
- 김민지; 한상환; 김태오
- 발행일
- 2021-07
- 저널명
- 한국지진공학회논문집
- 권
- 25
- 호
- 4
- 페이지
- 161 ~ 168