Quantitative evaluation of image quality restoration for short-acquisition brain PET using deep learning models and a dedicated three-dimensional-printed striatum phantom

  • Lee, Min-Gwan
  • Lee, Minkyu
  • Baek, Sora
  • kim, Ji Young
  • Chae, Sun Young
  • 외 1명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

This study evaluated the performance of U-Net and Nested U-Net in enhancing brain positron emission tomography (PET) image quality from 1-min acquisitions using a dedicated copper-based three-dimensional-printed striatum phantom. The phantom was fabricated with copper filament, filled with Fluorine-18, and imaged using a clinical digital PET/computed tomography scanner. A total of 500 paired datasets, consisting of 1-min input and 10-min reference images, were divided into training, validation, and test sets in an 8:1:1 ratio. The models were trained in PyTorch using the Adam optimizer. Performance was evaluated using the computational time, root mean square error (RMSE), peak signal-to-noise ratio (PSNR), universal quality index (UQI), learned perceptual image patch similarity (LPIPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV). The U-Net (15.9 h) required approximately 2.3 times less training time than the Nested U-Net (37.2 h). Both models substantially improved RMSE, PSNR, UQI, LPIPS, and CNR compared with the 1-min input images (p < 0.001). The U-Net achieved slightly superior RMSE, PSNR, and UQI compared to the Nested U-Net (p < 0.01), whereas both showed comparable LPIPS, CNR, and COV values. These results demonstrate that U-Net provides an effective balance between computational efficiency and quantitative accuracy for phantom-validated image quality restoration under short-acquisition PET conditions, which is directly relevant to applied PET imaging.

키워드

Positron emission tomography imagingShort-acquisition imagingThree-dimensional printed phantomQuantitative performance analysisDeep learning-based reconstruction3D reconstructionBrainComputational efficiencyCopperDeep learningImage acquisitionImage enhancementImage qualityImage reconstructionMean square errorMedical imagingMergers and acquisitionsPositron emission tomographyPositronsQuality controlRestorationSignal to noise ratioStatistical testsThree dimensional computer graphics
제목
Quantitative evaluation of image quality restoration for short-acquisition brain PET using deep learning models and a dedicated three-dimensional-printed striatum phantom
저자
Lee, Min-GwanLee, MinkyuBaek, Sorakim, Ji YoungChae, Sun YoungPark, Chanrok
DOI
10.1016/j.apradiso.2026.112818
발행일
2026-11
유형
Article
저널명
Applied Radiation and Isotopes
237
페이지
1 ~ 7