초록
Background and Objectives Accurate preoperative localization of abnormal parathyroid gland is essential for successful parathyroidectomy. The aim of this study was to evaluate the accuracy of a localization test for hyperparathyroidism including ultrasonography (US), computed tomography (CT) and 99mTc-sestamibi scan. Subjects and Method We studied 47 patients with hyperparathyroidism who underwent parathyroidectomy from January 2003 through December 2010, retrospectively. 99mTc-sestamibi scan, US and CT were carried out as a preoperative localization test and their accuracy were analyzed according to the size, location and pathology of parathyroid lesions. Results The accuracy of 99mTc-sestamibi scan, US and CT were 93%, 77% and 65%, respectively. The accuracy of 99mTc-sestamibi scan and CT combined was 94% and US and CT 73%. The accuracy of combination of US and 99mTc-sestamibi scan was 96%, which was not different depending on size, location and pathology of parathyroid lesions. Conclusion The combination of 99mTc-sestamibi scan and US is the most effective method for preoperative detection and the localization of hyperparathyroidism.
키워드
- 제목
- 부갑상선 기능 항진증에서 병변의 영상학적 진단과 위치 탐색 방법의 비교 연구
- 제목 (타언어)
- Comparative Study of Preoperative Imaging Detection and Localization Test for Hyperparathyroidism
- 저자
- 성의숙; 지용배; 최윤영; 김지영; 박정선; 이영준; 태경
- 발행일
- 2012-09
- 권
- 55
- 호
- 9
- 페이지
- 565 ~ 570