Sensor fault detection algorithm for IPMSM control system

Citations

SCOPUS

0

초록

This paper presents a new sensor fault detection algorithm for interior permanent magnet synchronous motor (IPMSM) control system. In order to derive the fault detection algorithm, this paper introduces a linearized IPMSM model transferred from nonlinear IPMSM model by the input-output linearization first. The input-output linearization provides a nonlinear coordinate transformation which linearizes the system dynamic equations. Therefore the linearized IPMSM model which reflects nonlinear properties of the IPMSM can be obtained by applying the inputoutput linearization. Second, this paper presents a residual generator derived from the linearized IPMSM model by applying the parity equation approach. Finally, the effectiveness of the proposed fault detection algorithm is verified by the computer simulation using an IPMSM model programmed by MATLAB/Simulink.

키워드

Input-output linearizationInterior permanent magnet synchronous motor (IPMSM)Parity equation approachSensor fault detectionComputer simulationControl systemsElectric vehiclesFault detectionLinearizationMathematical transformationsPermanent magnetsSignal detectionSynchronous motorsFault detection algorithmInput output linearizationInterior permanent magnet synchronous motorNonlinear coordinate transformationNonlinear propertiesParity equationResidual generatorSensor fault detectionAlgorithms
제목
Sensor fault detection algorithm for IPMSM control system
저자
Kim, JihwanJeon, NamjuLee, HyeongcheolJeong, Kiyun
발행일
2010-11
유형
Conference Paper
저널명
EVS 2010 - Sustainable Mobility Revolution: 25th World Battery, Hybrid and Fuel Cell Electric Vehicle Symposium and Exhibition