Computed Radiography 시스템에 192Ir과 75Se 동위원소를 적용하여 촬영한 비파괴검사 영상 비교

Comparison of Non-Destructive Testing Images using 192Ir and 75Se with Computed Radiography System
  • 강상묵
  • 최창일
  • 이승규
  • 박상기
  • 김용균

초록

A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy,radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using 75Se and 192Ir with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of 75Se and 192Ir.

키워드

이리듐-192셀레륨-75비파괴검사Computed RadiographySelenium-75Iridium-192Non-destructive testingComputed Radiography
제목
Computed Radiography 시스템에 192Ir과 75Se 동위원소를 적용하여 촬영한 비파괴검사 영상 비교
제목 (타언어)
Comparison of Non-Destructive Testing Images using 192Ir and 75Se with Computed Radiography System
저자
강상묵최창일이승규박상기김용균
발행일
2010-03
저널명
방사선방어학회지
35
1
페이지
26 ~ 33