수직-수평 팬 배치에 따른 라디에이터 냉각 효과 분석

Analysis of Radiator Cooling Effects According to the Vertical-Horizontal Fan Arrangement
  • 윤장혁
  • 이재철
  • 강태원
  • 이민재
  • 전종수
  • 외 1명

초록

In this study, the effect of radiator cooling according to the vertical–horizontal fan arrangement and fan performance was analyzed. Computational results and experimental data were compared to prove the validity of the computational fluid dynamics analysis method used in the study. The heat dissipation was affected by the collision effect of the fluid flows from the cooling fans. The newly created flows from the collision of the fluid flows occurred most in the S2B1 layout, and thus, the largest heat dissipation occurred in the S2B1 layout. The cooling efficiency was reviewed using the FOM formula. When the fan model was included in the S2B1 layout, the heat dissipation reduced by 5.38% compared to the conventional layout, but the cooling efficiency increased by 32.18%. As a result, the newly proposed S2B1 layout exhibited an improved cooling performance and efficiency.

키워드

CFDRadiator coolingFan arrangementHeat dissipationFactor of merit
제목
수직-수평 팬 배치에 따른 라디에이터 냉각 효과 분석
제목 (타언어)
Analysis of Radiator Cooling Effects According to the Vertical-Horizontal Fan Arrangement
저자
윤장혁이재철강태원이민재전종수양현익
DOI
10.7735/ksmte.2021.30.6.487
발행일
2021-12
저널명
한국생산제조학회지
30
6
페이지
487 ~ 494