Comparison of O-3 + GAC, O-3 + H2O2 + GAC, and GAC unit operation on natural organic matter and taste and odor causing compounds removal using a pilot plant study

  • Park, Hanbai
  • Kim, Tae-Yul
  • Woo, Dalsik
  • Cho, Yong-Sik
Citations

WEB OF SCIENCE

14
Citations

SCOPUS

15

초록

Removal of natural organic matter (NOM) and taste and odor problems in drinking water are a sensitive issue in municipal water treatment plants. This study investigated the effectiveness of ozone (O-3) + granular activated carbon (GAC), O-3 + hydroperoxide (H2O2) + GAC, and GAC processes using a pilot scale plant to remove NOM and geosmin (50-1,000 ng/L), and 2-methylisoborneol (2-MIB: 50-300 ng/L). In the O-3 + GAC process, NOM-related parameters showed an average of 52% dissolved organic carbon (DOC) removal from 2 mg/L DOC influent, 99.3% haloacetic acids (HAAs) removal from 0.097 mg/L HAAs influent, and 100% removal from 0.05 mg/L bromide influent. Taste and odor removal rates were 94-100% for geosmin and 87-100% for 2-MIB. The O-3 + H2O2 + GAC process removed an average of 55% DOC, 99.7% HAAs, 100% bromate, 94-100% geosmin, and 93-100% 2-MIB. The GAC process removed 46% DOC, 98.3% HAAs, 100% bromate, 83-100% geosmin, and 81-100% 2-MIB. Based on a comparison of the efficiencies and an economic analysis, the O-3 + H2O2 + GAC process was determined to be the optimal system for removing NOM and taste and odor compounds.

키워드

advanced oxidation processes (AOPs)GACgeosminhydrogen peroxideNOM2-MIBDRINKING-WATERBROMATE FORMATIONREMOVALGEOSMINOZONATIONOZONE2-METHYLISOBORNEOLOXIDATIONKINETICSMIB
제목
Comparison of O-3 + GAC, O-3 + H2O2 + GAC, and GAC unit operation on natural organic matter and taste and odor causing compounds removal using a pilot plant study
저자
Park, HanbaiKim, Tae-YulWoo, DalsikCho, Yong-Sik
DOI
10.2166/ws.2015.102
발행일
2015-12
유형
Article
저널명
Water Science and Technology: Water Supply
15
6
페이지
1383 ~ 1395