Feasibility study of β-ray detection system for small leakage from reactor coolant system

  • Jang, Jaeyeong
  • Jeong, Jae Young
  • Park, Junesic
  • Cho, Junesic
  • Pak, Kihong
  • ... Kim, Yong Kyun
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Because existing reactant coolant system (RCS) leakage detection mechanisms are insensitive to small leaks, a real-time, direct detection system with a detection threshold below 0.5 gpm∙hr−1 was studied. A beta-ray detection system using a silicon detector with good energy resolution for beta rays and a low gamma-ray response was proposed. The detection performance in the leakage condition was evaluated through experiments and simulations. The concentration of 16N in the coolant corresponding to a coolant leakage of 0.5 gpm was calculated using the analytic method and ORIGEN-ARP. Based on the concentration of 16N and the measurement of the silicon detector with 90Sr/90Y, the beta-ray count rate was estimated using MCNPX. To evaluate the effect of gamma rays inside the containment building, the signal-to-noise ratio (SNR) was calculated. To evaluate the count rate ratio, the radiation field inside the containment building was simulated using MCNPX, and response evaluation experiments were performed using beta and gamma rays on the silicon detector. The expected beta-ray count rate at 0.5 gpm leakage was 7.26 × 105 counts/sec, and the signal-to-background count rate ratio exceeded 88 for a transport time of 10 s, demonstrating its suitability for operation inside a reactor containment building.

키워드

16NBeta-ray detectorLeakage detection systemRCS leakageReactor coolant systemUnidentified leakageIONIZATION-ENERGYSILICON
제목
Feasibility study of β-ray detection system for small leakage from reactor coolant system
저자
Jang, JaeyeongJeong, Jae YoungPark, JunesicCho, JunesicPak, KihongKim, Yong Kyun
DOI
10.1016/j.net.2022.01.028
발행일
2022-07
유형
Article
저널명
Nuclear Engineering and Technology
54
7
페이지
2748 ~ 2754

파일 다운로드