상세 보기
초록
The oblique incidence technique for ultrasonic nonlinear characterization was studied in stainless steel 316L alloy subjected to high cycle fatigue. A dog-bone plate specimen was prepared to make different faitgue-driven deformation at each position where the stress concentration could occur in the middle of specimen. In addition to the normal transmission technique, the oblique incidence technique which is newly suggested in this study, was used to measure ultrasonic nonlinear parameter. The fatigued specimen shows higher ultrasonic nonlinear parameter than the virgin specimen for both techniques. Ultrasonic nonlinear parameter highly increases in the middle of test specimen where the stress concentration existes. Relative nonlinear parameter has strong correlation with fatigue damage. Consequently, the oblique incidence technique with longitudinal wave can be potential to characterize high cycle fatigue damage.
키워드
- 제목
- SUS316L 강의 초음파 비선형 특성평가를 위한 경사입사기법
- 제목 (타언어)
- Oblique Incidence Technique for Ultrasonic Nonlinear Characterization in SUS316L Alloy
- 저자
- 백승현; 이태훈; 김정석; 장경영
- 발행일
- 2010-08
- 저널명
- 비파괴검사학회지
- 권
- 30
- 호
- 4
- 페이지
- 345 ~ 351