상세 보기
탈황 흡수탑 유도전동기 베어링 결함 진단을 위한 전류 스펙트럼 해석
- 박정현;
- 문승재
초록
According to a research that is based on a previous study, But in a different way, This study shows fault diagnosis of Induction motor bearing which runs in coal-fired power plant industries on Desulfurization absorber agitator using Spectrum analysis of Stator Current and visual inspection. As a result of harmonic content analysis of stator current spectrum, It was possible to detect ball and outer race fault frequency. The comparison in the context of this experiment proves that the amplitude of faulty frequency is increased in three times at a fault in ball and in outer race. Spectrum analysis of stator current can be used to detect the presence of a fault condition as well as experiment in faulty bearings, besides early fault detection in bearings can prevent unexpected power generation loss and emergency maintenance cost.
키워드
- 제목
- 탈황 흡수탑 유도전동기 베어링 결함 진단을 위한 전류 스펙트럼 해석
- 제목 (타언어)
- Analysis of Motor-Current Spectrum for Fault Diagnosis of Induction Motor Bearing in Desulfurization Absorber
- 저자
- 박정현; 문승재
- 발행일
- 2015-06
- 유형
- 정기학술지(Article(Perspective Article포함))
- 저널명
- 플랜트 저널
- 권
- 11
- 호
- 2
- 페이지
- 39 ~ 44