The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.

키워드

Detector alignment and calibration methods (lasers, sources, particle-beams)Performance of High Energy Physics DetectorsResistive-plate chambersAstrophysicsCalibrationCharged particlesHigh energy lasersA-centerCalibration methodChemical damagesDetector performanceHigh energy physics detectorHigh voltageMuon triggerResistive plate chambersParticle spectrometers
제목
High voltage calibration method for the CMS RPC detector
저자
Reyes-Almanza, R.Dimitrov, A.Fagot, A.Gul, M.Roskas, C.Tytgat, M.Zaganidis, N.Fonseca De Souza, S.Santoro, A.Da Silva De Araujo, F. TorresAleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Shopova, M.Sultanov, G.Litov, L.Pavlov, B.Petkov, P.Petrov, A.Qian, S. J.Han, D.Yi, W.Avila, C.Cabrera, A.Carrillo, C.Segura, M.Aly, S.Assran, Y.Mahrous, A.Mohamed, A.Combaret, C.Gouzevitch, M.Grenier, G.Lagarde, F.Laktineh, I. B.Mathez, H.Mirabito, L.Shchablo, K.Bagaturia, I.Lomidze, D.Lomidze, I.Pant, L. M.Bhatnagar, V.Gupta, R.Kumari, R.Lohan, M.Singh, J. B.Amoozegar, V.Boghrati, B.Ghasemy, H.Malmir, S.Najafabadi, M. MohammadiAbbrescia, M.Gelmi, A.Iaselli, G.Lezki, S.Pugliese, G.Benussi, L.Bianco, S.Piccolo, D.Primavera, F.Buontempo, S.Crescenzo, A.Galati, G.Fienga, F.Orso, I.Lista, L.Meola, S.Paolucci, P.Voevodina, E.Braghieri, A.Montagna, P.Ressegotti, M.Riccardi, C.Salvini, P.Vitulo, P.Cho, S. W.Choi, S. Y.Hong, B.Lee, K. S.Lim, J. H.Park, S. K.Goh, J.Kim, T. J.Carrillo Moreno, S.Miguel Colin, O.Vazquez Valencia, F.Carpinteyro Bernardino, S.Eysermans, J.Pedraza, I.Uribe Estrada, C.Duran-Osuna, M. C.Ramirez-Garcia, M.Ramirez-Sanchez, G.Sanchez-Hernandez, A.Rabadan-Trejo, R. I.Castilla-Valdez, H.Radi, A.Hoorani, H.Muhammad, S.Shah, M. A.Crotty, I.
DOI
10.1088/1748-0221/14/09/C09046
발행일
2019-09
유형
Article; Proceedings Paper
저널명
Journal of Instrumentation
14
9
페이지